Airway
The Airway is intended for single use and are non-cleanable.
It is to be disposed after one CPR class (training session), if mouth-to-mouth ventilation has been performed.
This is also recommended if the Laerdal Manikin Face Shield has been used during the CPR training.
Illustration: Little Anne
Face mask and Face connector
To keep the manikin clean and in a hygienic condition, it is recommended to use a separate Laerdal Manikin Face for every student.
Manual Cleaning - during CPR class
If several students use one manikin face, thoroughly sanitize the manikin face after every use by using Manikin Wipes. This is also recommended if the Laerdal Manikin Face Shield has been used during the CPR training.
After CPR class
To keep the manikin clean and in a hygienic condition - clean all skin parts regularly, using one of the methods described below.
The parts can be cleaned by using manual processes (submerge item in water added cleaning detergent) or using an automatic cleaning process.
Manual Cleaning - after CPR class
Submerge for 20 minutes
For manual cleaning use one of the methods described below.
Soap solution
Sodium Hypochlorite
The Face mask and Face connector can be cleaned by Sodium Hypochlorite Solution (NaClO).
Sodium hypochlorite in solution exhibits broad spectrum anti-microbial activity and is widely used in healthcare facilities in a variety of settings.
Other chemicals to be used for manual cleaning
Some German companies have tested their products to be used for cleaning Laerdal Face Mask.
The Face Masks can be cleaned with the following chemicals without any degradation of the Product:
Chemicals from Bode Chemie:
Information about usage and Safety Data Sheets
Chemicals from EW80 System:
Information about usage and Safety Data Sheets
Automatic Cleaning - after CPR class
When using a washing machine use one of the methods described below.
Domestic Dishwasher
Meiko, Germany, has tested cleaning of face masks in their Multi-Washer systems, Top Clean 60 and Top Clean M using different detergents. The face masks can be cleaned using this system with the following chemicals without any degradation of the product:
Autoclaving |
Chest skin
The Chest skin can be cleaned by soap and hot water.
Skins with AED Electrodes and Chest skin patch inside, is cleaned with a clean dry cloth only. Moisture could damage the unit.
Hard plastic parts
Outside of Back section, Rib plate, Head and Jaw with Valve holder can be cleaned by soap and hot water, Resusci Manikin Wipes, 60% isopropanol or 70% ethyl alcohol.
Clothing
The Jacket and T-shirt can be cleaned by washing machine, at 40 °C (104 ºF).
The Baby Anne fabric body can be cleaned with a damp cloth only, using mild detergent if necessary. Users must take care not to expose the fabric body to excessive moisture, as this may penetrate the fabric and soak the manikin's stuffing.
QCPR Sensor and AED PC Board
The QCPR Sensor and AED PCB is cleaned with a clean dry cloth only. Moisture may damage the unit.