SimJunior represents a 6-year-old boy that simulates a wide range of conditions from a healthy, talking child to an unresponsive, critical patient with no vital signs.
SimJunior allows learners to focus on a broad range of pediatric skills in order to gain exposure and practical experience of life-threatening pediatric problems.
Available with a range of Technical and Educational Services, as well as validated simulation content, SimJunior presents a complete simulation solution for your pediatric training programs.
Whether using SimPad PLUS or a LLEAP PC to run your simulation, the software is easy and efficient to use for scenario based training. The intuitive operating platforms provide flexible management of patient parameters, integrated data and video capture, as well as simulated patient monitoring capabilities. Choose the operating systems that works best for your training needs.
Learner outcomes improve through structured debriefing after a simulation-based learning event. SimCapture seamlessly integrates with LLEAP (for PC and SimPad PLUS) providing a debriefing and assessment solution that captures audio, video, annotations, the patient monitor, and simulator data in a single web-based interface.
Learn more about simulation management with SimCapture
Integrating a simulated patient monitor enhances clinical realism and will challenge critical thinking skills. Laerdal patient monitoring software looks and responds like a real-world patient monitor, including:
|
|
In addition to the SimPad PLUS parameters, LLEAP also offers advanced patient parameters such as:
Multi Media functionality:
Breathing
Simulated spontaneous breathing
Observable chest rise
Variable respiratory rates
Multiple upper airway sounds synchronized with breathing
Detect mechanical ventilations (including no ventilations)
Bag Valve Mask capable
Normal and abnormal breath sounds
Oxygen saturation and waveform (Optional Patient Monitor)
Breathing complicationsLeft and right lungs can be either closed or opened to allow ventilations
Airway
The SimJunior airway is anatomically modeled as far as the trachea.
Realistic airway with landmarks
Oral and nasal intubation
LMA or ET insertion
Tongue oedema
NG tube
Cricoid cartilage
Head tilt and jaw thrust (no sensor)
Cardiac
Defibrillation and cardioversion
Pacing
Extensive ECG library
Multiple heart sounds synchronized with ECG
ECG rhythm monitoring (3 leads)
12 lead ECG display (Optional Patient Monitor)
Chest Compressions
Compliant with 2015 AHA and ERC Guidelines
CPR compressions generate palpable carotid pulses, blood pressure waveform, and ECG artifacts
Detection and logging of a series of compressions in the data log
Vascular Access
IV access (right arm and hand)
Intraosseous access (right tibia)
Circulation
Blood pressure measured manually by auscultation of Korotkoff sounds
Bilateral carotid and unilateral brachial and radial (left side) pulses synchronized with ECG
Pulse strength variable with BP
Pulse palpation is detected and logged
Sounds
Heart
Lung
Bowel
Patient voice
Pre-recorded sounds
Wireless microphone
Other Features
Interchangeable pupils
Session Viewer (PC operation)
Web-camera recording
Review event log together with synchronized recording of the patient monitor and in-room video
Patient Monitor (Optional)
Highly configurable
Simulates several parameters including:
Heart rate, ECG, SPO2, NIBP, ETCO2
12 lead ECG display